10        MergePoint 5224/5240 Service Processor Manager User Guide
Reset commands
Table 1.8 shows the reset options available when you are logged into the Web Manager, when you 
have selected a target device from the spshell menu on the MergePoint 5224/5240 SP manager 
console and when you are entering the ssh command on a remote workstation. The reset 
management options are only available for managed servers with SPs. 
The effects of the reset command differ from one vendor’s SP to another and sometimes between 
firmware versions from the same vendor. In addition, some SPs have more than one type of reset, 
as described in the following list:
Warm reset (or warm boot): only the server’s operating system is restarted
Cold boot: the server is fully restarted (the same effect as issuing a Power cycle command)
If an SP has more than one type of reset option, the MergePoint 5224/5240 SP manager Reset 
command performs the highest level of reset: the cold boot option if available.
If the administrator is configuring an SP that provides multiple reset options, the administrator can 
customize an associated SP management script to cause the reset command to perform one of the 
lower levels of reset available on the SP. Customizing SP management scripts is described in the 
MergePoint 5224/5240 Service Processor Manager Installer and Administrator Guide.
Sensor management options
An authorized user or administrative user can view graphical displays of sensor data collected from 
servers by their SPs. These users can also modify graph display settings through the Web Manager 
or the user shell menu or by using the ssh command with the sensor commands.
Figure 1.2 shows an example graph. The sensor value in a graph’s heading varies with the type of 
data being measured and the type of SP. The example fan sensor reading in Figure 1.2 has a 
heading Time Vs. % because the sensor is measuring the percentage of total possible fan speed. 
Examples of other possible values for sensor_value are Volts, Degrees Centigrade and 
Degrees Fahrenheit.
Table 1.8: Reset Options 
Method
Command or Option 
Web Manager
Reset
spshell menu in the MergePoint 5224/5240 SP 
manager console
reset
ssh command
reset