Chapter 4  Troubleshooting and Diagnostics 
IPmux-1/1E Installation and Operation Manual 
4-4  Diagnostic Tests
 
 
PBX
IPmux-1
 
Figure 4-1.  IPmux-1 External Loop 
Internal Loop 
The E1/T1 module can be set to an internal loop to test the connection between 
the E1/T1 port and the IP network (refer to Chapter 3). In this mode (E1/T1 only), 
data coming from the IP network is both looped back to the IP network and an AIS 
pattern is transmitted forward to the PBX connected to the E1/T1 port (see 
Figure 4-2).  
PBX
AIS
IPmux-1
 
Figure 4-2.  IPmux-1 Internal Loop 
➤ 
To run a loopback test: 
•  Press the <Spacebar> on your keyboard to toggle between the values:  
Internal/External /Disable
−  Internal:  Data received from the IP network side is looped back to the 
network transmit line. An unframed all ‘1’ code (AIS) is transmitted in the 
E1 Tx path toward the PBX. Incoming data from the PBX is ignored. 
−  External:  Data received from the PBX at the receive E1 line is looped back 
to the E1 Tx path (toward the same PBX), and continues its way to the  
IP network. Data coming from the IP network is ignored. 
−  Disable:  No loopback. Regular operation.  
Default value: Disable 
BRI 
External Loop 
An external loop on IPmux-1E can be set to test the ISDN “S’ line (Figure 4-3). The 
test is performed on B channels only.  
IPmux-1
ISDN S
 
Figure 4-3.  IPmux-1E/BRI External Loop 
 
Internal Loop 
An internal loop on IPmux-1E can be set to test the ISDN “S’ line (Figure 4-4). The 
test is performed on B channels only.  
Main Menu 
         ↓ 
2. Configuration 
         ↓ 
2. E1/T1 
Configuration 
        ↓ 
3. Loopback 
State  