Saving and restoring configuration settings
The AdderView CATx 1000 can store up to 256 computer names and 5 sets 
of user access rights in addition to the ADMIN user account. Particularly in 
cascaded configurations, manually re-entering all computer names, port 
numbers and access rights can be a lengthy process. Therefore, the AdderView 
CATx 1000 provides a method to save and, if required, restore configuration 
settings using its serial port. Further to this, the saved file can be opened 
and edited within a text editor or spreadsheet and then restored back to the 
AdderView CATx 1000 – a useful way to make multiple setup changes. 
Note: You must be logged-in as the ADMIN user for this procedure. 
Preparations for configuration save/load 
•  Download the Adder Data Transfer utility - contact Adder Technical Support 
for details.
•  Connect the serial port on the rear panel of the AdderView CATx 1000, 
labelled 
OPTIONS
, to a serial port on your computer using the optional serial 
 for pin-out specifications. 
To transfer configuration settings
1  Run the Adder Data Transfer utility on the computer that is connected to the 
AdderView CATx 1000 Options serial port. The utility has a single window: 
2  Click the Configuration button and ensure that the appropriate serial port of 
the computer is selected.
3  Click the Browse... button to locate or create a text file that will either 
provide or receive the AdderView CATx 1000 data.
4  Choose the direction of data flow:
•  Click the Unit to File button to download the existing AdderView CATx 
1000 configuration to the selected text file, or
•  Click the File to Unit button to upload the contents of the file to the 
AdderView CATx 1000 unit.
  A pop-up dialog box will request you to set-up the unit to either send or 
receive RS232 data.
5  Using the local port of the AdderView CATx 1000 unit, display the 
Note: You must be logged-in as the ADMIN user.
6  Select the ‘Functions’ option.
7  Select either ‘Send Data to RS232 port’ (if you chose the Unit to File button) 
or ‘Read Data from RS232 port’ (if you chose the File to Unit button). 
8  On the computer, click the OK button of the pop-up dialog box to begin 
downloading or uploading. The process will end automatically when all data 
have been transferred.   