Configuring a Blade Chassis Device Connected to KX2 
Blade Chassis Overview 
There are two types of blade chassis devices: one is with an integrated 
KVM switch, which can function as an IP-enabled KVM switch, and the 
other is without. 
 
Blade Chassis with an Integrated KVM Switch 
A blade chassis with an integrated KVM switch, such as Dell PowerEdge 
and IBM BladeCenter series, is connected to KX2 via a CIM. As only one 
CIM is available to access all blade servers in that chassis, when a user 
accesses one blade server, there are no paths left to the others. 
When configuring all KX2 ports in CC-SG, the blade chassis connected 
to the KX2 device is configured. See 
Add a Blade Chassis Device
 (on 
page 64). The blade servers in this type of blade chassis are not 
configured yet, so you must configure the blade servers later. See 
Configuring Slots on a Blade Chassis Device
 (on page 65)
 
Blade Chassis without an Integrated KVM Switch 
A blade chassis without an integrated KVM switch, such as HP 
BladeSystem series, allows each blade server to connect to KX2 
respectively via a CIM. As each blade server in that chassis has a CIM 
for access, when a user accesses one blade server, others still can 
access the other blade servers. 
When configuring all KX2 ports in CC-SG, the blade servers connected 
to the KX2 device are configured. If you have properly configured a blade 
port group for these blade servers on the KX2 device, CC-SG then 
creates a virtual blade chassis at the KX2 port level as the container for 
these blade servers. See 
Add a Blade Chassis Device
 (on page 64)
Otherwise, these blade servers appear as normal KX2 ports in the 
Devices tab of CC-SG.