Chapter 6: Devices, Device Groups, and Ports 
 
 
77
 
 
Adding Devices with CSV File Import 
You can add devices to CC-SG by importing a CSV file that contains the 
values. You must have the Device, Port, and Node Management and CC 
Setup and Control privileges to import and export devices. 
You must be assigned a policy that gives you access to all relevant 
devices and nodes. A full access policy for All Nodes and All Devices is 
recommended. 
Note: You cannot add P2SC devices with CSV file import. 
 
Devices CSV File Requirements 
The devices CSV file defines the devices, ports, and their details 
required to add them to CC-SG. 
 
For devices that support power strips connected to a port (SX, KX, 
KX2, KSX2), configuring the port will configure the power strip. 
 
If device ports are configured, CC-SG also adds a node with 
out-of-band KVM or out-of-band Serial interface for each port. 
 
To add blades, the blade server must be connected to a KX2 device 
via a CIM. The KX2 device must either already be added to CC-SG, 
or be included in the same CSV file. 
 
Export a file from CC-SG to view the Comments, which include all 
tags and parameters needed to create a valid CSV file. See 
Export 
Devices
 (on page 82)
 
Follow the additional requirements for all CSV files. See 
Common 
CSV File Requirements
 (on page 369)
 
To add a device to the CSV file: 
Column 
number 
Tag or value 
Details 
ADD 
The first column for all tags is the 
command ADD. 
DEVICE 
Enter the tag as shown.   
Tags are not case sensitive. 
Device Type 
Required field. 
Enter the device type as shown here: 
KX, KX2, KSX, KSX2, KX101, 
KX2-101, IP-Reach, SX, or PX 
Device Name 
Required field. 
Device names cannot contain