Power ON Self-Test 
Every DPR-1061 has been factory-tested to operate properly. 
 
When the DPR-1061 is powered ON, it also automatically performs a Self-Test on 
each of its major components. The final result of the Self-Test is signaled by the state 
of the USB1, USB2 and LPT LED indicators following the Self-Test. Preliminary to 
the actual component tests, the three LED indicators are tested to confirm their 
steady and flashing operation. 
 
Immediately after power-up, all five of the green LEDs should illuminate steadily for 
several seconds. Then the USB1, USB2 and LPT LEDs should light OFF 
simultaneously. Irregularity of any of the three LEDs during these LED tests may 
mean there is a problem with the LEDs themselves. 
 
The actual component tests immediately follow the LED tests. A normal (no fault) 
result is signaled by a simultaneous flashing of these three LEDs three times, 
followed by a quiescent state with all three LEDs dark. 
 
If the Self-Test routine traps any component error, then following the LED tests the 
Self-Test will halt and the LEDs will continuously signal the error according to the 
following table. In the event of any such error signal, contact your dealer for 
correction of the faulty unit. 
LED 
USB1 USB2  LPT 
Faulty Component 
On 
DRAM error
 
1 long 3 short
 
Flash Protected
 
1 long 5 short
 
Flash Erase/Program error
 
1 long 6 short
 
LAN Controller error