Adder Technology AdderLink IP Manuel D’Utilisation

Page de 64


20
Power switching configuration
Power switch configuration comprises two main steps:
•  Configure the COM2 serial port to the same speed as used by the power 
switch box(es) - see 
 for details. 
•  Configure power ON and OFF strings for each relevant host computer.
For each power port there needs to be a valid ‘Power ON string’ and similarly an 
appropriate ‘Power OFF string’. In each case, the strings are a short sequence of 
characters that combine a port address and a power on or off value. 
If a particular computer has more than one power input (and thus requires an 
equivalent number of power ports to control them), collections of strings can be 
combined to switch all of the required ports together as a group.
To configure the power sequences for each host computer
1  Using VNC viewer or a browser, log on as the ‘admin’ user.
2  Click the ‘Configure’ button in the top right corner.
3  Click the ‘Host configuration’ option.
4  Click one of the 32 host entry slots to display a Host configuration dialog:
Power control sequences
Note: The settings given below are for the EPS-S8 power switch - other power 
switches may require different settings. Please refer to your power switch 
documentation for details about codes required by other power switches.
The structure of each power sequence (OFF and ON) is as follows:
Pxy=z\0D 
   Where: 
x is the switch box number,
y is the power port number,  
z is ‘0’ for OFF or ‘1’ for ON, and
\0D represents Enter (or Carriage return).
Example 1 
To switch ON port 5 of switch box 2, the code would be as follows:
•  Power sequence:  
P25=1\0D
Example 2 
To switch OFF port 8 of switch box 3, the code would be as follows:
•  Power sequence:  
P38=0\0D
For details about operating this feature, see 
 within the 
Operation chapter.
To control two or more ports simultaneously
You can control up to four power ports using a single sequence. You merely 
use the same command structure, as shown above, repeated on the same line 
for each port. A 1 second delay is automatically inserted by the AdderLink IP 
between each port control code. 
5  If necessary, configure other parameters (Name, Users, Hot Keys - 
).
6  Enter the 
Power control sequences in the Power On and Power Off fields 
ð
7  Click OK to close the dialog and then click the Save button in the main Host 
Configuration window to store the details.