TP-LINK TL-SL2210WEB/TL-SL2218WEB Manuel D’Utilisation

Page de 64
      34
Gigabit Uplink Web Smart Switch 
Storm Control
Figure 6-25 
Broadcast Control: 
 
¾
Enable or disable the broadcast control to limit the broadcast 
frames.
Multicast Control: 
 
¾
Enable or disable the multicast control to limit the multicast 
frames. Enabling multicast control will also enable broadcast control.
UL Control: 
 
¾
Enable or disable the UL control to limit the UL packets. Enabling UL 
control will also enable broadcast control and multicast control.
Limit  Rate: 
 
¾
Indicates  the  maximum  rate  (kilobytes  per  second1  at  which  the 
controlled packets configured above are forwarded. For the 1000Mbps port, if set 
the value of 64Kbps, the actual value is about 70Kbps.
Note: 
Parameters of Trunk member ports display the parameters of the Trunk 
they belong to and it cannot be configured here (see port 5 and 6 in  Figure 6-25 
for example1. You can configure parameters of the Trunk in the “Port Trunking” 
page.
Port DescriCtion
511111C 
This page configures the description to indicate the ports.
Input description words in the Description filed for each port. Notice that at most 15 
letters or numbers can be held in each field.
Port Description
Figure 6-26 
Web Management