Raritan Computer DKX2-V2.3.5-0N-E Manuel D’Utilisation

Page de 351
Chapter 8: Device Management 
 
140
 
 
 
Device Services 
The Device Services page allows you to configure the following 
functions:   
 
Enable SSH access. 
 
Enable tiering for the base KX II. 
 
Enter the discovery port. 
 
Enable direct port access. 
 
Enable the AKC Download Server Certificate Validation feature if you 
are using AKC.   
 
Enabling SSH 
Enable SSH access to allow administrators to access the KX II via the 
SSH v2 application. 
 
To enable SSH access: 
1.  Choose Device Settings > Device Services. The Device Service 
Settings page opens. 
2.  Select Enable SSH Access. 
3.  Enter the SSH Port information. The standard SSH TCP port number 
is 22 but the port number can be changed to provide a higher level of 
security operations. 
4.  Click OK. 
 
HTTP and HTTPS Port Settings 
You are able to configure HTTP and/or HTTPS ports used by the KX II. 
For example, if you are using the default HTTP port 80 for another 
purpose, changing the port will ensure the device does not attempt to 
use it. 
 
To change the HTTP and/or HTTPS port settings: 
1.  Choose Device Settings > Device Services. The Device Service 
Settings page opens. 
2.  Enter the new ports in the HTTP Port and/or HTTPS Port fields. 
3.  Click OK.