Chapter 8: Device Management 
 
158
 
 
 
4.  Click OK. 
Note: If either of these checkboxes is selected and power input is not 
actually connected, the power LED at the front of the unit turns red. 
 
To turn off the automatic detection: 
  Deselect the checkbox for the appropriate power supply. 
 
To reset to factory defaults: 
 
Click the Reset To Defaults button. 
Note: The KX II does NOT report power supply status to 
CommandCenter. Dominion I (generation 1), however, does report 
power supply status to CommandCenter. 
 
Configuring Ports 
The Port Configuration page displays a list of the KX II ports. Ports 
connected to KVM target servers (blades and standard servers) and rack 
PDUs (power strips) are displayed in blue and can be edited. For ports 
with no CIM connected or with a blank CIM name, a default port name of 
Dominion-KX2_Port# is assigned, where Port# is the number of the KX II 
physical port.   
 
To access a port configuration: 
1.  Choose Device Settings > Port Configuration. The Port Configuration 
Page opens. 
This page is initially displayed in port number order, but can be 
sorted on any of the fields by clicking on the column heading. 
  Port Number - Numbered from 1 to the total number of ports 
available for the KX II device. 
  Port Name - The name assigned to the port. A port name 
displayed in black indicates that you cannot change the name 
and that the port cannot be edited; port names displayed in blue 
can be edited. 
Note: Do not use apostrophes for the Port (CIM) Name. 
  Port Type   
Port type 
Description 
DCIM 
Dominion CIM 
Not Available 
No CIM connected 
PCIM 
Paragon CIM