Lucent Technologies 555-233-115 Manuel D’Utilisation

Page de 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
What’s New in Release 8.2r 
xi
 
Tools
No new tools became available with Release 8.2r.
Commands, screens, and fields
No new commands and screens became available or were affected by Release 
8.2r.
Procedures
The following procedures and steps changed or were added because of 
problems identified in the laboratory or during early introduction. 
Many of the upgrade procedures were reordered and the steps within the 
procedure better defined. Check the task tables at the beginning of each 
upgrade chapter for the current order. 
Also, to reduce redundancy in the book, there is no longer a separate upgrade 
process for high or critical reliability. The procedures and steps that apply to high 
or critical reliability are noted where they occur in the upgrade process.
Procedure
Steps
Notes
1. Type status spe and press 
Enter
 to check the health of 
the SPE. 
Becomes first step of 
upgrade procedure
1. Insert the TN1650B 
memory circuit pack in 
memory slot 3.
Adding memory to the 
standby SPE causes an error 
because the memory number 
between the standby and 
active carriers does not 
match.
This requires an additional 
power down of the carrier.