Actron 9640 Manuel D’Utilisation

Page de 156
Help & Troubleshooting 
9 – 2 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 
ERROR MESSAGES
If the tool exhibits a problem when 
communicating with the vehicle, a 
message displays. The vehicle’s control 
module(s) enters into an unrecoverable 
state. Press 
ENTER and the tool resets.
Operating Error or Erroneous Data
An Operating Error or Erroneous Data 
occurs if the vehicle’s computer(s) stops 
communicating with the scan tool. When 
this happens, the scan tool prompts you 
to try again or return to the Function 
List. Make a selection and press 
ENTER. 
Measure Voltage between 
BAT + and GND pins.
frame ground.
Above 8V?
less than
5 ohms?
Is
battery fully 
charged?
Contact Customer 
Service Center.
Repair Ground
circuit. Refer to a 
service manual.
Charge battery.
Scan Tool
 does not 
power up.
NO
NO
NO
YES
YES
YES
Open exists in power 
circuit. Check for a blown fuse 
or an open wire. Refer to a 
service manual.
PIN 16 (BAT+)
PIN 4 (GND)
PIN 2 (BAT+)
PIN 6 (GND)
J1962 (OBD II) DLC
LH DLC
Vehicle Comm Fault. ?
 Turn Key Off For
10 Sec, Then Press
ENTER To Reset Tool~
Operating Error
Check Connections!
Try Again?
  <YES>      NO
~