Mitsubishi Electronics 882.00273.00 Manuel D’Utilisation

Page de 101
Figure 66: Typical Engineering Only Setup Screen 
Go back to 
Setup 
Directory 
 
Factory Setup Menu 
Metering Test Screen 
This screen is useful in both R & D and development purposes when testing the metering 
performance of each feeder.   The user can perform a “Single Meter by Weight” to evaluate 
the mechanical standard deviation of the gate or auger.  This test meters for the calculated 
time based off the target weight entered on this screen.  The blender does not retry or adjust 
the time of the meter to reach the target, but instead always meters for the same amount of 
time as long as the target weight has not been changed.  This allows you to open the gate for 
several feeds using the same amount of time.  You can then record the Dispensed Grams and 
plot the standard deviation of the gate.  The other purpose of this screen is to verify that the 
dispensed weight displayed is correct.  You can perform a meter and then pull the weigh 
hopper to weigh the material on a gram scale.  The value on the screen should match the 
measurement on the gram scale.  If it does not, then either the weigh hopper is not balanced 
correctly or the scale calibration is not correct.  Refer to the Troubleshooting Section of this 
manual for additional details. 
Figure 67: Typical Metering Test Screen 
 
Target Weight 
Meter Data 
Stop the Meter 
Change Method 
Go back to  
Engineering 
Only Directory 
Select a Feeder 
Advanced Weight Options Screen 
This screen allows you to modify the weight filter, adjust the mechanical time to settle the 
weigh hopper after dumping, adjust the mechanical time to settle after a feeder has introduced 
material into the weigh hopper, adjust the Maximum Empty Weight of the hopper, and to 
enable the batch weight data to be dumped to a printer every batch for diagnostic purposes.  
The data that is dumped to a printer is the same data shown on the Recipe Screen.  No 
averaging is done with the data shown to the Customer.  Targets vs. Actual are actually what 
is in the batch without any “smoke and mirrors.” 
The weight filter is the specialized filter algorithm that smoothes erroneous load cell 
readings.  The signal will be filtered more if this value is increased and less if decreased.  
BF1-615.3 
Chapter 7: 6BAppendix 
87 of 101