Bunn S Manuel D’Utilisation

Page de 44
Page 29
3.
Check  voltage  across  the  WHI  wire  from  the
terminal block and the wire from the "ON/OFF"
switch to the  warmer element  with a voltmeter
with the  "ON/OFF" switch in the "ON" position.
The indication must be:
a) 120 volts ac for two wire 120 volt versions.
b)  120  volts  ac  for  three  wire  120/208  volt
versions or 120/240 volt versions.
4.
Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to wiring
diagrams and check brewer wiring harness.
5.
Check the continuity across the two terminals on
the warmer element.
If continuity is present as described, reconnect the
wires on the warmer element.
If continuity is not present as described, replace the
warmer element.
Removal and Replacement:
1.
Remove  the  three  #4-40  screws  securing  the
warmer assembly to the brewer.
2.
Lift the warmer assembly from the brewer.
3.
Disconnect the two wires from the warmer ele-
ment terminals.
4.
Remove the two #8-32 nuts securing the warmer
element to the warmer plate.
5.
Securely install new warmer element.
6.
Reconnect  the  two  wires  to  warmer  element
terminals.
7.
Securely install warmer assembly on the brewer.
8.
Refer to FIG. 23 when reconnecting the wires.