Bunn JDF-4SB Manuel D’Utilisation

Page de 57
35
SERVICE (CONT.)
Cold Water Dispense Switch (JDF-4S only)
FIG. 43 COLD WATER DISPENSE SWITCH
P1449
FIG. 44 COLD WATER SWITCH TERMINALS
BLK
BLU
Location:
  The cold water dispense switch is located on the 
lower outside of the dispenser door.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Remove the five screws attaching the dispenser 
door cover to the door and move the door cover 
to gain access to the switch.
3.  With a voltmeter, check the voltage across the two 
wires for the dispense switch. Connect the dispenser 
to the power source. The indication must be +5 
volts dc.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the Wiring 
Diagrams and check the dispenser wiring harness.
4.  Check for continuity across the terminals (top right 
to top left) of the dispense switch with the switch in 
the “ON” position. Continuity must not be present 
when the switch is in the “OFF” (released) posi-
tion.
If continuity is present as described, reconnect the door 
wiring harness, the switch is operating properly.
If continuity is not present as described, replace the 
switch.
Removal and Replacement:
1.  Disconnect the dispenser from the power source.
2.  Remove the five screws attaching the dispenser 
door cover to the door and move the door cover 
to gain access to the switches.
3.  Disconnect the wires on the dispense switch from 
the door wiring harness.
4.   Compress the clips inside the door on the dispense 
switch and gently push the switch through the 
opening.
5.  Push new switch into the opening and spread the 
clips to hold the switch in the door.
6.  Reconnect the wires to the dispense switch from 
door wiring harness.
7.   Reinstall the door cover and secure with the five 
screws previously removed.
8.  Refer to Fig. 44 when reinstalling wires. 
49179  110613