Bunn JDF-4SB Manuel D’Utilisation

Page de 57
46
SERVICE (CONT.)
Temperature Probe (all Models)
FIG. 65 TEMPERATURE PROBE
FIG. 66 TEMPERATURE PROBE
Location:
 
The temperature probe is located on the top of the 
tank assembly.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Remove the top rear cover.
3.  With a voltmeter, back probe the connector from 
the temperature probe.
4.  Connect the dispenser to the power source.
5.  See the chart for voltage readings.
6.  For continuity check, disconnect the dispenser 
from the power source.
7.  Disconnect the two pin connector from the dis-
penser main wiring harness.
8.  With an ohmmeter, check for continuity across 
the pins for the black and white wires.
9.  See the chart for resistance/voltage readings. Al-
ternate check: Leave two pin connector plugged 
in, place dc voltmeter across two pin connector in 
parallel, check voltage with dispenser running.
10. Verify wiring to probe.
11. If readings are not present as described, replace 
the temperature probe.
NOTE: Some meters have difficulty measuring a sen-
sor either rapidly rising or falling in temperature.
Removal and Replacement:
1.  Disconnect the dispenser from the power source.
2.  Remove the top rear cover.
3.  Disconnect the two pin connector from the dis-
penser main wiring harness.
4.  Remove the temperature probe by firmly pulling-
up on the tube at the tank lid. This will disengage 
the grommet from the tank lid.
5.  Slide a new grommet on to the new temperature 
probe.
6.  Insert the temperature probe through the hole 
in the tank lid and press the grommet firmly and 
evenly so that the groove in the grommet fits into 
the tank lid.
7.  Reconnect the two pin connector to the dispenser 
main wiring harness.
BLKor ORN pin 1
WHI pin 2
 TEMP 
RESISTANCE 
VOLTAGE
 
  SHORTED 
0 Ω 
0VDC
 
32° F 
31.2k - 34k Ω 
3.0VDC
 
0.0° C
 
77° F 
9.8k - 10.2k Ω 
1.5VDC
  25.0° C
 
OPEN 
INFINITE 
5.0VDC
NOTE: ALL FIGURES LISTED ABOVE ARE APPROXIMATE.
49179  012214