Smeg CS150SA Manuel D’Utilisation

Page de 43
7
Instructions for the Installer
2.2
Electrical connection
Check that the voltage and size of the power supply line are as specified
on the nameplate inside the storage compartment. 
This nameplate must never be removed.
The plug on the end of the power supply cable and the wall socket must be
of the same type (in compliance with the relevant national standards).
Check that the power supply line is properly earthed. The use of
reductions, adapters or junctions is not recommended.
The appliance's power supply line must be fitted with an omnipolar
breaking device with contact gap of at least 3 mm, located in an easily
accessible position close to the appliance itself.
The appliance has a terminal
board on its rear.
To access it, remove the back
cover.
Make the electrical connection
in accordance with the wiring
diagram shown below.
Operation at 380-415V3N~:  use a
H05RR-F or H05RN-F five-wire cable
(cable of 5 x 2.5 mm2).
Operation at 380-415V2N~:  use a
H05RR-F or H05RNF four-wire cable
(cable of 4 x 4.0 mm2).
Operation at 220-240 V~: use a H05RR-F
/ H05RNF three-wire cable (cable of 3 x 6
mm2).
The earth wire (yellow-green) must be at
least 20 mm longer than the other wires at
the end for connection to the appliance.