Sanyo CG1411 Manuel D’Utilisation

Page de 100
21
6.  ELECTRICAL DATA
6-1.  Electrical Characteristics
Indoor unit
KGS1411
Outdoor unit
CG1411
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
115V Single phase 60Hz
Rating conditions
Running amp.
A
0.35
0.64
7.2
8.2
Power input
kW
0.033
0.077
0.79
0.90
Full load conditions
Running amp.
A
0.35
0.64
9.0
10.0
Power input
kW
0.033
0.077
0.99
1.10
Rating conditions:
Indoor air temperature
80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor air temperature
95°F (35°C) D.B. 
Full load conditions: Indoor air temperature
95°F (35°C) D.B. / 70°F (21.2°C) W.B.
Outdoor air temperature
115°F (46.1°C) D.B. 
Rating conditions:
Indoor air temperature
70°F (21.1°C) D.B. 
Outdoor air temperature
47°F (8.3°C) D.B. / 43°F (6.1°C) W.B.
Full load conditions: Indoor air temperature
80°F (26.7°C) D.B. 
Outdoor air temperature
75°F (23.9°C) D.B. / 65°F (18.3°C) W.B.
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
115V Single phase 60Hz
Rating conditions
Running amp.
A
0.35
0.64
4.9
5.9
Power input
kW
0.033
0.077
0.51
0.62
Full load conditions
Running amp.
A
0.35
0.64
5.8
6.8
Power input
kW
0.033
0.077
0.61
0.72
Heating
Cooling