Whirlpool AKM 441/IX AKM441IX Fascicule

Codes de produits
AKM441IX
Page de 2
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: If the distance “A“ between the wall cabinets is between 600 mm and 680 mm, the 
height “B” must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the 
cooktop, the height “B” must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the hood 
instructions for the correct distance.
INJECTORS TABLE
CATEGORY II2H3+
ELECTRIC SUPPLY: 230 V 50 Hz
Type of gas used
Type of 
burner
Injector 
marking
100/mm
Rated 
heat 
capacity
kW
Rated 
consumption
Reduced 
heat 
capacity 
kW
Gas pressure
mbar
min.
rat.
max.
NATURAL GAS
(Methane)
G20
large
medium
small
128
94
76
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
0.60
0.35
0.30
17
20
25
LIQUID PETROLEUM 
GAS
(Cylinder)
G30
large
medium
small
85
65
50
3.00
1.65
1.00
218 g/h
120 g/h
73 g/h
0.60
0.35
0.30
20
28-30
35
LIQUID PETROLEUM 
GAS
(Cylinder)
G31
large
medium
small
85
65
50
3.00
1.65
1.00
214 g/h
118 g/h
71 g/h
0.60
0.35
0.30
25
37
45
Type of gas used
Appliance
model
Total rated heat 
capacity kW
Total rated 
consumption
Air required
for burning
m3/h
G20 20 mbar
4 gas
7.30
695 l/h
14.6
G30 28-30 mbar
4 gas
7.30
531 g/h
14.6
G31 37 mbar
4 gas
7.30
521 g/h
14.6