Jacuzzi J-345 Manuel D’Utilisation

Page de 72
49
J-300
14.0  Error Conditions/Error Messages
Your spa has a self-diagnostic control system. The system will 
automatically display the following if a problem is detected. 
Always 
insist on genuine Jacuzzi replacement parts.
14.1  Summer Logic
When the actual spa water temperature reaches 2°F (1°C) 
above the set temperature, the spa goes into “summer logic.” 
The circulation pump will turn off automatically, if running, to 
avoid adding additional heat to the water, eventually creating 
an overheat condition. This setting is not user-programmable.
Note: Summer logic does not take effect until the spa water temperature 
reaches 95°F (35°C). This condition is more likely in excessively hot 
weather. Remember, the spa’s ability to cool is directly affected by 
the ambient temperature. An excessively hot ambient temperature 
may prevent the spa from cooling down because it’s fully insulated 
construction is designed to retain heat and minimize operating costs.
14.2  Panel Displays COL
Cool Condition - Temperature has dropped 20°F (11°C) 
below the current set temperature. Jets pump 1 and the 
heater have been activated to bring the temperature within 15°F (8°C) of 
the set temperature. No corrective action is required!
Note: This condition is common during first time fill ups or during refills 
since tap water is often very cold. “COL” will only appear when the spa is 
in Economy mode.
14.3  Panel Displays ICE
Freeze Protection - A potential freeze condition has been 
detected. No action is required. Jets Pump 1 and heater will 
activate to circulate and warm water through the plumbing until spa is out 
of danger. See “Winterizing” (page 42).
14.4  Panel Displays SN1
Open sensor (heater is disabled) or shorted sensor (spa 
is deactivated). The high-limit temperature sensor is not 
functioning. Contact your authorized Jacuzzi dealer or qualified service 
technician.
14.5  Panel Displays SN2
Open or shorted sensor (heater disabled). The temperature 
sensor is not functioning. Contact your authorized Jacuzzi 
dealer or qualified service technician.
14.6  Panel Displays BLB
UV bulb needs to be replaced. The message will flash 
between “blb” and the water temperature. The countdown 
be purchased from a local Jacuzzi dealer.