C2. 
ATTACH THE MOUNTING PLATE
TO THE WALL (cont.)
To use toggle bolts:
3.
Place the mounting plate against the wall and 
insert the toggle wings into the holes on the wall to 
mount the plate.
NOTE: Before tightening toggle bolts and wood 
screw, make sure to coincide bottom line of the 
Mounting plate with Horizontal line of “Rear wall 
Template” and then the Mounting plate is properly 
centered under the cabinet.
CAUTION: Be careful to avoid pinching fingers 
between the back of the mounting plate and the wall.
4.
Tighten all bolts. Pull the plate away from the wall 
to help tighten the bolts.
C3.
USE TOP CABINET TEMPLATE 
FOR PREPARATION OF TOP 
CABINET
You need to drill holes for the top support screws and 
a hole large enough for the power cord to fit through.
Read the instructions on the TOP CABINET 
TEMPLATE.
Tape it underneath the top cabinet.
Drill the holes, following the instructions on the 
TOP CABINET TEMPLATE.
CAUTION: Wear safety goggles when drilling holes in 
the cabinet bottom.
Wall
Bolt End
Toggle Wings
Toggle 
Bolt
Spacing for Toggles More 
Than Wall Thickness
Mounting 
Plate
C4. 
ADAPTING MICROWAVE 
BLOWER FOR OUTSIDE BACK 
EXHAUST 
1.
Remove the back top center blower motor door 
retaining screw.
2.
Open the blower motor by lifting it up at the back 
side of the microwave. Remove and save the top 
and back retaining screws that hold the blower 
motor in the microwave.
3.
Carefully slide the blower motor toward the right, 
and lift it partially out of the opening. Note: The 
blower wires are long enough to allow flexible 
handling while performing these steps. 
Disconnect the wires if necessary for additional 
flexibility.
4.
Remove the two screws holding the left side inlet 
sleeve to the blower unit. Snap the inlet sleeve 
off of the blower.
Blower Motor
Back of 
Microwave
Blower Motor
Screw
Retaining
Screw
Retaining
Screw
Remove