IBM 570 Manuel Du Matériel Informatique
Symptom-to-FRU index
Symptom or error
FRU or action, in
sequence
sequence
02F5
DIMM test failure
DIMM test failure
1. DIMM.
2. System board.
2. System board.
02F6
Software NMI failure
Software NMI failure
1. DIMM.
2. System board.
2. System board.
02F7
Fail—safe timer NMI failure
Fail—safe timer NMI failure
1. DIMM.
2. System board.
2. System board.
Error messages
Symptom or error
FRU or action, in
sequence
sequence
Device address conflict
1. Load Setup Defaults
in IBM BIOS Setup
Utility.
Utility.
2. Backup battery.
3. System board.
3. System board.
Allocation error for: device
1. Load Setup Defaults
in IBM BIOS Setup
Utility.
Utility.
2. Backup battery.
3. System board.
3. System board.
Failing bits: nnnn
1. DIMM.
2. System board.
2. System board.
Invalid system configuration
data
data
1. DIMM.
2. System board.
2. System board.
I/O Device IRQ conflict
1. Load Setup Defaults
in IBM BIOS Setup
Utility.
Utility.
2. Backup battery.
3. System board.
3. System board.
Operating system not found
1. Enter IBM BIOS
Setup Utility and see
whether the hard disk
drive and diskette
drive are properly
identified.
whether the hard disk
drive and diskette
drive are properly
identified.
2. Diskette drive.
3. Hard disk drive.
4. System board.
44
ThinkPad 570 and 570E Hardware Maintenance
Manual