Bakers Pride 101 Manuel D’Utilisation

Page de 12
G. LEAK TESTING:
·
The  plumbing  must  now  be  tested  for  gas  leaks  before  use.  Turn  all  propane  tank,  burner  control  and 
carryover control valves to the OFF position. Wet all gas line fittings and connectors with a solution of soapy water (or 
commercial leak disclosing liquid). Slowly open the propane tank valve(s) and look for bubbles of foam at any of the 
joints of the system. If a leak is found, close the tank valves immediately and call your local dealer or the manufacturer. 
If the gas connections are leak-free, the unit is ready to use. Follow the lighting instructions.
Side Rack Installation:
!
Side racks have to be installed on both sides of the 60" stand and on the right side of the 30" stand if your 
unit  came  with  20  lb  LP  cylinders.  Optional  40  lb  horizontal  cylinders  come  with  single  or  double  tank 
caddy.
!
Attach the tank rack to the side of the stand with two 1/4-20" thumb screws provided (see fig. A-1). Make   
sure the screws are properly tightened.
!
Clamp mounting bracket to the legs with the clamps and fasten with (2) thumb screws.
!
Hang the 20lb cylinder on the rack with service valve outlet  facing the front of the unit (see fig. A-2)
!
Fasten the tank with tank brace and wingnut.
!
Make sure the tanks are secure in their racks and can not move
2. LIGHTING INSTRUCTIONS
A. LIGHTING INSTRUCTIONS: Fill water pans to within ½" of top edges (this will control grease flare-ups, provide for 
ease of cleaning and keep cooked food moist). Re-fill pans with water when they evaporate to within ½" of the bottom 
of the pans. Failure to keep water in the water pans could lead to grease fires and will void the warranty.
1.
Check that the tank mounting brackets are securely mounted on the unit.
2.
Open the roll-up hood if so equipped. Turn all the burner knobs and carryover tube knobs to the OFF position   
and slowly open the gas tank valves.
3.
Turn the carryover tube knob on one side fully counter-clockwise to the ON position. Insert a lit, extra long               
 match or a gas lighter flame though the hole on the same side in the front panel. For 60” broilers repeat the             
 same procedure for the other side.
4.
Check that the entire crossover tube is lit by looking through the lighter hole(s) located on the front panel. If the 
carryover tube(s) will not light or stay lit, shut off the gas supply and do not use the unit. Wait 5 minutes before   
attempting to re-light the unit. (See Figure “B”)
5.
After  lighting  the  crossover  tube(s),  open  the  desired  burner  valves  and  observe  that  the  burners  light                           
completely from the crossover tube(s).
 
iqqqqqq
F. INSTALLING OPTIONAL TANK CADDY:
!
If you unit is equipped with optional 
tank  caddy,  it  has  to  be  placed 
underneath the broiler and secured 
in place by (2) hooks provided (see 
fig. “A-3”). The front of the caddy will 
be raised off the ground to prevent 
possible  movement  and  putting 
strain on connection hoses.
!
LP  gas  cylinder(s)  have  to  be 
securely mounted to the caddy with 
thumb screws. They will only work in 
the horizontal position.
Figure “A-3”
Black Plastic 
Connector
Tank Caddy (Single)
Hook