REFILL VALVE - EARLY MODELS
Location:
 
The refi ll valve is located inside the front of the 
brewer.
Test Procedures:
1.    Enter programming level 2, scroll to "Service Tools" 
then scroll to "Refi ll Valve".
2.  Briefl y activate the refi ll valve in the test mode. 
With a voltmeter, check the voltage across the coil 
wires.
3.  The indication must be 120 volts ac for two wire 120 
volt models and three wire 120/208 -240 volt models 
or 230 volts ac for two wire 230 volt models.
If voltage is present, proceed to # 4.
If voltage is not present, refer to Wiring Diagrams 
and check main wiring harness. If harness checks 
ok, replace control board.
4. Check 
the 
refi ll valve for coil action. Briefl y activate 
the refi ll valve in the test mode and listen carefully near 
the refi ll valve for a"clicking" sound  as the magnetic 
coil pulls the plunger in.
If the sound is heard as described and water will 
not pass through the refi ll valve, there may be a 
blockage in the water line before the refi ll valve or, 
the solenoid valve may require inspection for wear, 
and removal of waterborne particles.
If the sound is not heard as described, proceed to 
# 5.
5.  Disconnect the brewer from the power source. 
6.  Check for continuity across the refi ll  valve  coil 
terminals.
If continuity is not present as described, replace 
the refi ll valve.
If continuity is present as described, there could be 
some debris in the valve.
Removal and Replacement:
1.  Remove both wires from the refi ll valve.
2.  Verify that the white shutoff clamp between valve 
and tank is squeezed shut.
3.  Disconnect both water lines at the valve.
4.  Remove the two 1/4"-20 screws securing the valve 
to the component mounting  bracket. 
5.  Using the two 1/4"-20 screws, install the new valve 
to the component mounting bracket.
6.  Securely fasten the water lines to the valve.
7.  Refer to wiring diagrams when reconnecting the 
wires.
8.  Install access panels and covers and refer to Initial 
Set-up for refi ll and operation.
FIG. 18-2  REFILL VALVE
FIG. 18-1  REFILL VALVE
39132 041708