Bunn cdbcf 15 Mode D'Emploi

Page de 48
Page 9
DIAGNOSTICS
PROBABLE CAUSE
REMEDY
MESSAGE
"CHECK  SPRAYHEAD FOR LIME" - 
"CHECK FITTINGS FOR LIME"
Clean sprayhead
Clean valve
Clean tank
1. Lime buildup in sprayhead
2. Lime buildup in brew valve
3. Lime buildup in brew tank
"WARNING INACCURATE FLOW" 
- "TOO MUCH LIME PLEASE RE-
PAIR"
Clean sprayhead
Clean valve
Clean tank
1. Lime buildup in sprayhead
2. Lime buildup in brew valve
3. Lime buildup in brew tank
"WARNING VERY LOW FLOW" - 
"PLEASE REPAIR"
Clean sprayhead
Clean valve
Clean tank
1. Lime buildup in sprayhead
2. Lime buildup in brew valve
3. Lime buildup in brew tank
Temperature Too Low
Heating Time Too Long
Fill Time Too Long
Temp Sensor Out Of Range, Check 
For Bad Connections
Temp Sensor Out Of Range, Check 
Wire For Shorts
1. Water temperature in the tank 
does not meet the ready tempera-
ture.
1. Tank Heater failure.
2. Control Board/Thermistor fail-
ure
1. Water shut off to brewer
2. Supply line too small or ob-
structed
3. Inlet Solenoid failure
4. Control Board Failure
5. ON/OFF switch is OFF
1. Temperature Sensor Probe 
open
1. Temperature Sensor Probe 
wire(s) shorted
A)  Wait for the brewer to heat to 
the proper temperature.
B) Disable the BREW LOCKOUT 
function.  Refer to programming 
section for procedure.
Replace or repair as needed
Replace or repair as needed
Check water supply shut-off
Replace or repair as needed
Replace or repair as needed
Replace or repair as needed
Turn switch ON
Replace or repair as needed
Replace or repair as needed
39132 041708