THERMAL FUSES
FIG. 18 THERMAL FUSES
P2759.40
Location:
The thermal fuse is located inside the rear of the
hood connected to the right front  tank heater terminal.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Disconnect the thermal fuse from the right tank
heater terminal black wire lead.
3. With an ohmmeter, check for continuity across the
thermal fuse terminals.
If continuity is present as described, the thermal fuse
is operating properly.
If continuity is not present as described, replace the
thermal fuse.
Removal and Replacement:
1. Disconnect the thermal fuse from the  tank heater
and black lead of the control thermostat.
2. Remove thermal fuse and discard.
3. Connect new thermal fuse to the tank heater termi-
nal and black lead.
4. Refer to Fig. 19 when reconnecting thermal fuse.
FIG. 19 THERMAL FUSE TERMINALS
P2751.75
SERVICE (cont.)
36102 090203
Thermal Fuse toControl
Thermostat