DISPENSE SWITCH(S) - FMD-1 & FMD-2
FIG.14 DISPENSE SWITCH
P1614
Location:
 
The dispense switch(es) is (are) located on 
the lower outside of the dispenser door.
Test Procedure:
FMD-1
FMD-2
SERVICE (cont.)
7.   Check the voltage across the red (+) terminal  and 
the black (-) terminal of the auger motor with a 
voltmeter.  Connect  the  dispenser  to  the  power 
source. Press and hold the appropriate dispense 
switch.    After  a  delay  of  about  .6  seconds,  the 
indication must be between +4.0 and +24.5 volts 
dc.
If the voltage is present as described, the hopper motor 
control circuitry is operating  properly.
If the voltage is not present as described, replace the 
control circuit board.
Removal and Replacement:
1.  Disconnect the three plugs on the main wiring har-
ness from the connectors on the control board.
2.  Remove the four #6-32 keps nuts securing the 
control board to the component bracket.
3.  Remove control board and discard.
4.   Install new control board on the component bracket 
using four #6-32 keps nuts.
5.  Reconnect the three plugs on the main harness to 
the connectors on the control board.
J4
J2
J3
J1
J1              J4       
FIG. 13 CONTROL BOARD CONNECTORS
P1640
CONTROL BOARD - FMD-2 ONLY (CONT.)
J2   J3
29112 101598