SERVICE (cont.)
Limit Thermostat
P1993
FIG. 5 LIMIT THERMOSTAT
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.   There are two black wires on the limit thermostat 
terminals. One comes from the terminal block. The 
other goes directly to the tank heater terminal. Re-
move the black wire at the limit thermostat coming 
from the terminal block.
3.  Check the voltage across the black wire removed 
from the limit thermostat and the red wire of the 
terminal block with a voltmeter. Connect the dis-
penser to the power source. The indication must be 
200 to 240 volts ac for 200 to 240 volt models.
4.  Disconnect the dispenser from the power source.
Reset
BLK to Terminal Block
BLK to Tank Heater
P1776
FIG. 6 LIMIT THERMOSTAT WIRING
Limit Thermostat
Location:
The limit thermostats are located on the tank lid.  To test 
the limit thermostats, access will also be needed to the 
terminal block located on the side of the dispenser.
If voltage was present as described, reconnect the black 
wire and proceed to #5.
If voltage was not present as described, refer to the 
Wiring Diagrams and check the dispenser wiring har-
ness.
5.  Check for continuity across the terminals of the 
limit thermostat.
If continuity is not present as described, the circuit is 
broken. Press the reset button of the limit thermostat 
and recheck for continuity.
If continuity is not present as described, replace the 
limit thermostat.
Removal and Replacement:
1.  Remove both wires from the limit thermostat ter-
minals.
2.  Remove the two #10-32 nuts attaching the limit 
thermostat to the top of the tank.
3.  Install  the  new  limit  thermostat  and  secure  into 
place with two #10-32 nuts.
4.  Refer to FIG. 6 when reconnecting the wires.
10889 091599