Bunn single tf brewwise dbc Mode D’Emploi

Page de 54
Page 37
PROGRAMMING THE BREWER (cont.)
SERVICE TOOLS
 
This function allows the testing of individual com-
ponents and the ability to check switches for proper 
function. This function also tests the Soft Heat server's 
status on the brewer (in place or removed), and the 
funnel  sensor  coil's  frequency  (diagnostic  tool  for 
troubleshooting purposes only).
EXIT TO
NEXT FUNCTION
SCREEN
EXIT TO
NEXT FUNCTION
SCREEN
PRESS AND RELEASE
® SYMBOL
PRESS AND RELEASE
® SYMBOL
NEXT COMPONENT
TO BE TESTED
TEST OUTPUTS?
NO                     YES
TEST SWITCHES?
NO                     YES
BREW VALVE
ON      NEXT      OFF
125.0 KHZ.    4
4     125.0 KHZ.        
NOTHING PRESSED
TEST FREQUENCY?
NO                     YES
SERVICE TOOLS?
NO                     YES
P2757
Testing individual components (outputs):
 
This will allow the operator to test the operation 
of individual components and outputs of the brewer.  
The components that can be individually tested are as 
follows:
Brew Valve
Bypass Valve
Funnel Lock (Optional)
Refill Valve
Tank Heaters
Heater Contactor
Procedure to test components (outputs):
1.  Place brew funnels into rails on the brewer.
2.  Place a Soft Heat server beneath the brew fun-
nel.
3.  Press and hold the upper right hidden switch until 
the display reads UNITS. Release the switch, then 
press and release switch until the display reads 
SERVICE TOOLS.
4.  Press YES to run tests on various components 
and outputs within the brewer. Pressing NO will 
exit this function and advance to the next function 
screen.
5.  The display should read TEST OUTPUTS.
6.  Press and release YES. The display should read 
BREW VALVE.
7.  To test BREW VALVE, press ON. If the brew valve 
is functional, water should run from the brewer.
8.  Press OFF to end flow of water.
9.  Press NEXT to advance to the next component to 
be tested.
NOTE: To bypass testing any component, press NEXT 
to advance to the next one, without testing the previ-
ous component.
10. To test BREW BYPASS, press ON. If the bypass 
valve is functional, water should run from the  brew 
bypass.
11. Press OFF to end flow of water.
12. Press NEXT to advance to the next component to 
be tested.
13. To test FUNNEL LOCK, press ON. If the funnel lock 
is functional, the lock will come down to hold the 
funnel in place.
35879.1 071405