Before First Use 
 
What you should expect to find in the carton 
Check to be sure that all of the following items have been included 
in the carton along with this manual: 
 
1 compressor freezer, model SPRF26 
 
1 DC/DC power cord 
 
1 AC/DC adapter 
 
Clean Before Using 
After you remove the unit from its packaging, clean the inside  be-
fore using.  See cleaning instructions in the Cleaning  section of 
this manual. 
 
Installation 
 
1.  Place cooler on a dry surface where it is protected from water. 
2.  The cooler should not be used where it may be exposed to rain. 
3.  Never locate the cooler where the ambient temperature is be-
low 0°C (32°F). 
 
ALLOW COOLER TO SIT UPRIGHT FOR 24 HOURS BEFORE 
TURNING ON, TO ALLOW THE COMPRESSOR LUBRICANT TO 
DRAIN. 
 
Keep flammable materials and vapors such as gasoline away from 
appliances.  Failure to do so can result in fire or explosion. 
  
Electrical Connection 
The cooler can be operated from either a DC or an AC power 
source.  Both require the use of the DC/DC power cord included 
with the unit.  With an AC source, the included AC/DC adapter 
must be plugged into the end of the DC/DC power cord, then con-
nected to an AC source such as a wall socket. 
 
DC Source: The cooler can be operated between 10.3V and 17V 
DC, or between 22V and 30V DC.  Before connection, check 
that the battery voltage falls within these ranges.  If the voltage 
is out of range, the cooler will not operate.  Excessive voltage 
could damage the electronic components of the cooler. 
 
AC Source: Be sure to use the AC/DC adapter when your power 
source is AC, otherwise the cooler could be damaged.