Nokia 5110 Instruction De Maintenance

Page de 12
NSE–1
System Module UP8S
Original 03/98
3/A3–S11
ac–level
dc–level
condition
name
testpoint ref
J516
VSYN_1 ( regulated supply for VCOs)
2.8 V min 2.7 / max 2.85 V
J518
VREF_2 ( ref. voltage for N500 )
1.5 V +/– 1.5%
J520
AFC ( autom. freq. cntrl )
0 – 2.3 V, typ. 1.15 V ( room temp. )
J522
VXO ( regulated supply for VCTCXO )
2.8 V min 2.7 / max 2.85 V
J530&J532
71 MHz IF input to N620
–95 dBm @ X540
(ext. RF connector )
typ. ca. 1.2 V pulsed
typ 100 – 140 uVpp balanced voltage at 71 MHz
J540
13 MHz output from N620 to Z620
–95 dBm @ X540
(ext. RF connector )
RXC at level of full
calibrated gain
typ. ca. 1.5 V pulsed
typ. ca. 700 uVrms
J550 & J552
116 MHz TX IF to N500
typ. ca. 1.1 – 1.2 V pulsed
typ. ca. 100 mVrms each
J562
RXC ( receive gain control voltage )
RX gain setting depended
control range is 0.5 – 1.45 V, ,pulsed.
typ. 1.3–1.4 V for calibrated maximum gain
Layout Diagram of UP8S – Bottom 
(Version 9)
testpoint ref
name
condition
dc–level
ac–level
J101
FBUS_TX
active state
pulsed DC (0V72.8V)
J104
CCONTCSX (CCONT chip select)
active state
pulse active 0V, non–active 2.8V
J108
CHRG_CTRL
charger connected
pulsed DC (0V/2.8V)
J220
V5V
active state
nominal 5.0V (min 4.8V, max 5.2V)
J223
CCONTINT (charger, RTC interrupt)
interrupt
 pulse active 2.8V, non–active 0V
J225
EXTSYSRESETX
power on
reset state 0V, normal state 2.8V
J226
VCXOPWR
power on
active state 2.8V, non–active 0V
J227
PURX (power on reset)
power up/down
reset state 0V, normal state 2.8V
J228
SLEEPCLK (32kHz clock)
power on
pulsed DC (0V/2.8V)
J235
ROM1SELX
active state
pulse active 0V, non–active 2.8V