Nokia 5110 Instruction De Maintenance

Page de 68
PAMS
Technical Documentation
NSE–1/3
Service Software Instructions
Page  34
Original 03/98
Testing
The Testing sub menu offers functions for ME testing.
RF Controls... command
Activation
Status Bar Text
Alt, E,R
Open RF Controls dialog box
This function is used for RF testing.
Command opens RF Controls dialog, which contains data for testing and
adjustments.
Dialog mode: modal
RF Controls dialog has following items:
Active Unit group:
RX radio button (ALT+R):
When 
RX
 is selected, the next functions are made:
Data transmission is deactivated
TX power is deactivated
If operation mode is continuous,
– AGC is controlled
– RX continuous mode channel is activated
RF Information window is updated
The RX value is always given as default.