Check Operation
Electronic Ignition System
Cooktop and oven burners use electronic ignitors in place of
standing pilots. When a cooktop control knob is turned to the
“LITE” position, the system creates a spark to light the burner.
This sparking continues until the control knob is turned to the
desired setting.
When the oven control is turned to the desired setting, a hot sur-
face ignitor heats to a bright orange and ignites the gas. No
sparking occurs. The glow bar remains on while the burner oper-
ates.
Check Operation of Cooktop Burners
1. If control panel and knobs were
removed earlier, reinstall knobs.
2. Push in and turn each surface
unit control knob to “LITE” posi-
tion. The flame should light with-
in 4 seconds. 
3. Turn control knob to “HI” posi-
tion after burner lights. 
4. Check each cooktop burner for
proper flame. The small inner
cone should have a very distinct blue
flame 
¹⁄₄" (6.4 mm) to ¹⁄₂" (13 mm) long.
The outer cone is not as distinct as the
inner cone. 
5. Turn the control knob quickly to the “LO”
position after the burner lights. If the
flame goes out, turn the control knob to the “OFF” position.
6. Check each cooktop burner for proper low flame. The low
flame should be a minimum, steady blue flame. The flame size
should be 
¹⁄₄" to ³⁄₈" (6.4 mm to 9.5 mm) high.
If the low flame needs adjusting: 
1. Turn control knob to the “LO” setting and remove control
knob.  
2. Insert a small flat-blade screwdriver into the valve stem. Turn
the valve adjusting screw to obtain the smallest flame that will
not go out when the control of a cold burner is quickly turned
from “HI” to “LO”. Turn right to decrease flame height. Turn
left to increase flame height. Repeat for other cooktop burners
as needed.
3. Replace control knob.
Complete Connection
1. Locate gas pressure regulator in the broiler.
IMPORTANT:
Do not remove the gas pressure regulator. 
2. Check that the gas pressure regulator shutoff valve is in the
“ON” position.
3. Open the manual shutoff valve in the gas supply line. The
valve is “open” when the handle is parallel to the gas pipe.
4. Test all connections by brushing on an approved noncorrosive
leak-detection solution. Bubbles will show a leak. Correct any
leak found.
5. Close the broiler door.
6. Place burners, burner caps and grates on the cooktop.
7. Plug into a grounded 3-prong outlet.
OFF
LO
LITE
MED
HI
outer
cone
inner
cone
A. Closed valve
B. Open valve
A
A. Gas pressure regulator
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
A
Shutoff valve
“ON” Position
Front
Front View
Front View
Side View
Gas Pressure Regulator
A. Valve stem
A