SimpleTech Zeus Ultra Manuel D’Utilisation

Page de 48
Functional Description
ATA Commands
22
 Zeus Ultra DMA Solid State Drives
2.4.2
Standard ATA Commands
Table 7 lists each command along with its respective command code and registers 
accessed by the command. For detailed descriptions of the ATA commands, refer to the 
ATA-5 specification.
Table 7.
Supported ATA Commands
Command
Command 
Code (Hex)
Feature 
Register
Sector 
Count 
Register
Sector 
Number 
Register
Cylinder 
High/Low 
Register
Drive/Head 
Number 
Register
CHECK POWER MODE
98 or E5
No
Yes
No
No
Yes 
a
a.
Only drive parameters are valid.
ERASE SECTOR
C0
No
Yes
Yes
Yes
Yes 
b
b.
Drive and head parameters are valid.
EXECUTE DRIVE 
DIAGNOSTIC
90
No
No
No
No
Yes 
c
c.
Address to drive 0 (zero). When executed, Both drives (master and slave) execute this command).
FORMAT TRACK
50
No
Yes
No
Yes
Yes 
(b)
IDENTIFY DRIVE
EC
Yes
No
No
No
Yes 
(a)
IDLE
97, E3
No
Y
No
No
Yes 
(a)
IDLE IMMEDIATE
95, E1
No
No
No
No
Yes 
(a)
INITIALIZE DRIVE 
PARAMETERS
91
No
Yes
No
No
Yes 
(b)
READ MULTIPLE
C4
No
Yes
Yes
Yes
Yes 
(b)
READ SECTOR(S)
20
No
Yes
Yes
Yes
Yes 
(b)
READ VERIFY SECTOR(S)
40
No
Yes
Yes
Yes
Yes 
(b)
RECALIBRATE
10
No
No
No
No
Yes 
(a)
SEEK
70 - 7F
No
No
Yes
Yes
Yes 
(b)
SET FEATURES
EF
No
Yes
Yes
Yes
Yes 
(b)
SET MULTIPLE MODE
C6
No
Yes
No
No
Yes 
(a)
SET SLEEP MODE
99 or E6
No
No
No
No
Yes 
(a)
STANDBY
96 or E2
No
Yes
No
No
Yes 
(a)
STANDBY IMMEDIATE
94 or E0
No
No
No
No
Yes 
(a)
WRITE MULTIPLE
C5
No
Yes
Yes
Yes
Yes 
(b)
WRITE SECTOR(S)
30
No
Yes
Yes
Yes
Yes 
(b)