IMPORTANT SAFETY INFORMATION
Continued from page 3
15.  An  unvented  gas-fired  heater  uses  air  (oxygen) 
from the room in which it is installed. Provisions for 
adequate combustion and ventilation air must be 
provided. See installation guidelines. 
16.  Keep room area clear and free from combustible 
materials,  gasoline  and  other  flammable  vapors 
and liquids.
17.  Unvented  gas  heaters  are  a  supplemental  zone 
heater. They are not intended to be a primary heat-
ing appliance.
18.  Unvented gas heaters emit moisture into the living 
area. In most homes of average construction, this 
does not pose a problem. In houses of extremely 
tight construction, additional mechanical ventilation 
is recommended. 
19.  During  manufacturing,  fabricating  and  shipping, 
various components of this appliance are treated 
with  certain  oils,  films  or  bonding  agents. These 
chemicals are not harmful but may produce annoy-
ing smoke and smells as they are burned off during 
the initial operation of the appliance; possibly caus-
ing headaches, or eye or lung irritation. This is a 
normal and temporary occurrence.
    The initial break-in operation should last two to three 
hours with the burner at the highest setting. Provide 
maximum ventilation by opening windows or doors 
to allow odors to dissipate. Any odors remaining 
after this initial break-in period will be slight and will 
disappear with continued use.
20.  Input ratings are shown in BTU per hour and are for 
elevations up to 2,000 feet. For elevations above 
2,000 feet, input ratings should be reduced 4 per-
cent for each 1,000 feet above sea level. Refer to 
the National Fuel Gas Code.
21.  The  appliance  and  its  appliance  main  gas  valve 
must be disconnected from the gas supply piping 
system during any pressure testing of that system 
at test pressures in excess of 1/2 psig (3.5 kPa).
22.  The appliance must be isolated from the gas supply 
piping system by closing its equipment shutoff valve 
during any pressure testing of the gas supply piping 
system at test pressures equal to or less than 1/2 
psig (3.5 kPa).
23.  Do not use this room heater if any part has been 
under  water.  Immediately  call  a  qualified  service 
technician to inspect the room heater and to replace 
any part of the control system and any gas control 
which has been under water.
24.  Never  burn  solid  fuels  in  a  fireplace  where  a 
unvented room heater is installed.
25.  Always have a fireplace screen in place when the 
appliance is in operation, and unless other provi-
sions for combustion air are provided, the screen 
shall have an opening(s) for induction of combus-
tion air.
26.  Do not fill spaces around the firebox with insulation 
or  other  materials. These  spaces  must  be  main-
tained to prevent the firebox from coming in contact 
with combustible materials. 
www.nficertified.org
We suggest that our gas hearth 
products be installed and 
serviced by professionals who 
are certified in the U.S. by the 
National Fireplace Institute
®
 
(NFI) as Gas Specialists. 
Never connect unit to private 
(non-utility) gas wells.  This 
gas is commonly known as 
wellhead gas.
W
ARNING