Hanna Instruments hi 8757 Manuel D’Utilisation

Page de 2
ACCESSORIES
OPERATIONAL GUIDE
Remove the battery cover on the back of the thermometer.
Unwrap the supplied 9V battery, connect it to the battery
clip and reattach the cover.
Connect the temperature probe to the connector on the top
of the meter.
To switch ON, turn the rotary
knob to the ºC or ºF position
(depending on the model).
The meter displays the percent-
age indication of the remaining
battery life for a few seconds, and
then enters measurement mode.
If a temperature probe is plugged in, the meter displays
the measured temperature either in °C (HI 8757) or °F (HI
8758), automatically switching to the resolution suitable to
the temperature range; i.e. 0.1° up to 199.9°C (399.9°F),
or 1° above.
If no probe is plugged in, or if
reading is over-range, the dis-
play shows flashing dashes.
If a measurement is slightly over the range of the meter
specifications, the display flashes the closest full-scale value.
To switch the thermometer OFF,
turn the rotary knob to OFF.
FACTORY RECALIBRATION
All Hanna thermometers have been accurately pre-cali-
brated at the factory. It is generally recommended to have
all thermometers recalibrated at least once a year.
For an accurate annual recalibration, contact your dealer or
the nearest Hanna Service Center.
BATTERY REPLACEMENT
The instrument is powered by a 9 V battery and  is
provided with Battery Error Prevention System (BEPS),
which turns the unit off when a low battery signal is
detected.
When the battery level is less than
10%, a warning symbol blinks
on the display to indicate a low
battery condition.
It is recommended to replace the battery as soon as the low
battery condition is detected.
Remove the cover on the meter's back by applying pressure
in the indicated direction. Unplug the rundown battery
and replace it with a new one.
Battery replacement must only take place in a nonhazard-
ous area using a 9V alkaline battery.
Recommendations for Users
Before using these products, make sure that they are entirely suitable for the environment in which
they are used.
Operation of these instruments in residential areas could cause unacceptable interference to radio
and TV equipment, requiring the operator to take all necessary steps to correct interference.
Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC
performance.
To avoid electrical shock, do not use these instruments when voltage at the measurement surface
exceeds 24VAC or 60VDC.
To avoid damage or burns, do not perform any measurement in microwave ovens.
CE DECLARATION OF CONFORMITY
K-TYPE THERMOCOUPLE PROBES
with integral handle, 1 m (3.3’) cable & mini-connector:
HI 766A
Roller surface probe, max 320°C/600°F
HI 766B
Surface probe, max 650°C/1200°F
HI 766B1
90º Surface probe, max 450°C/840°F
HI 766B2
Spring-loaded, surface probe, max
900°C/1650°F
HI 766B3
Spring-loaded, small surface probe with
insulated shaft, max 200°C/390°F
HI 766C
Penetration probe, max 900°C/1650°F
HI 766C1
Ultra-fast Penetration probe, max 300°C/
570°F
HI 766D
Air probe, max 300°C/570°F
HI 766E1
General purpose probe, max 900°C/1650°F
HI 766E2
General purpose probe, max 900°C/1650°F
HI 766F
High temperature, flexible wire probe
without handle, max 1100°C/2000°F
HI 766F1
Flexible wire probe without handle, max
480°C/ 900°F
HI 766TR1
Penetration probe, max 250°C/482°F
HI 766TR2
Penetration long probe, max 250°C/482°F
HI 766TV1
Pipe clamp probe, max 200°C/390°F
with detachable handle & mini-connector (to be used
in conjunction with the HI 766HD probe handle):
HI 766PA
Roller surface probe, max 320°C/600°F
HI 766PB
Surface probe, max 650°C/1200°F
HI 766PC
Penetration probe, max 900°C/1650°F
HI 766PD
Air probe, max 300°C/570°F
HI 766PE1
General purpose probe, max 900°C/1650°F
HI 766PE2
General purpose probe, max 900°C/1650°F
grill surface probe:
HI 766B4
Grill surface probe with 70 cm (27.6’’)
cable (protected with stainless steel jacket),
max 250°C/482°F
HI 7664B4S
Spare stainless steel sensor for HI766B4 probe
OTHER ACCESSORIES
HI 710002
Soft carrying case
HI 710009/10
Blue/Orange rubber boot
HI 710031
Hard carrying case
HI 721310
9V Battery (10 pcs)
HI 766EX
Extension cable for K-type probes
HI 766HD
Rugged thermocouple probe handle with
1m (3.3') cable fitted with mini-connector
ACCESSORIES
ISTR8757       01/03