INSTALLATION 
2.6.4 RS485 
Master/Slave 
 
The RS485 master/slave connection is used to collect data from several scanners to 
build a multi-point or a multi-sided reading system; there can be one master and up 
to 5 slaves connected together. 
The slave scanners are connected together using RS485 half-duplex on the main 
serial interface. Every slave scanner must have a multidrop address in the range 0-4. 
The master scanner is also connected to the Host on the RS232 auxiliary serial 
interface. 
The External Trigger signal is unique to the system; there is a single reading phase 
and a single message from the master scanner to the Host computer. 
It is necessary to bring the External Trigger signal to all the scanners. 
The main and auxiliary ports are connected as shown in the figure below. 
 
 
c
 Auxiliary Serial Interface (RS232) 
d
 Main Serial Interface (RS485 Half-Duplex) 
e
External Trigger 
Figure 25 - RS485 Master/Slave Layout 
 
 
NOTE 
The auxiliary serial interface of the slave scanners can be used in 
Local Echo communication mode to control any single scanner 
(visualize collected data) or to configure it using the WinHost utility or 
Host Mode Programming procedure. 
The termination resistors of the RS485 bus must not be installed. 
 
23