lift-master htl Manuel D’Utilisation

Page de 20
OPTIONAL SETTINGS
Set
max.
run
timer
Set
adj.
mid
stop
Set
timer
to close
Diagnostic
mode
1
2
3
OFF
4
1
2
3
OFF
4
1
2
3
OFF
4
1
2
3
OFF
4
Set Maximum Run Timer
Begin with door in closed position. Set dip switch to max. run timer
mode. Press control station open button to operate door from closed to
full open position without stopping. Set dip switch to desired operating
mode (B2, C2, D1, E2, T, TS).
Set Adjustable Mid Stop
Begin with door in closed position. Set dip switch to adj. mid stop mode.
Press control station open button to operate door from closed to mid
stop position and stop with control station stop button. Set dip switch to
desired operating mode (B2, C2, D1, E2, T, TS).
Set Timer to Close (NOTE: Requires P/N 1A4811 CPSII Option
Board with Timer to Close Function)
Set dip switch to timer to close mode. Momentarily press control station
open button to set timer duration in 5 second increments. (Red
diagnostic L.E.D. will flash to indicate the entry of each 5 second
increment into memory). To re-set timer memory to zero, press control
station close button. Set dip switch to (T or TS) operating mode after
timer is programmed.
Diagnostic Mode
Set dip switch to diagnostic mode. Flashing red diagnostic L.E.D.
indicates proper microprocessor function. If the diagnostic L.E.D. does
not light, the control logic board requires replacement.
13
1
2
3
4
5
6
7
8
9
10
L3
L2 H
L1 N
TB1-
1
2
3
Open
Open / Close
RADIO CONTROL
(24V dc only)
Stop
Sensing Device
208-230V, 3Ø
208-230V, 3Ø
208-230V, 3Ø
Close
STANDARD POWER AND
CONTROL CONNECTION DIAGRAM
(Solid State Board CDO - 208-230V, 3Ø)
GND