Serial Control Processor (Room Control Interface) 
The Executive Elite Base DSP is capable of being monitored and controlled via 
a control system. Communication can either be over the serial port of the 
Executive Elite, or over an IP connection.  If several Executive Elite Base DSPs 
are part of an installation, each requires its own connection to the control 
system in order to communicate. 
 
To use the control system API, the External Control Configuration setting the 
type of external processor and the connection method has to be defined to 
match the external control system’s settings. 
 
Executive Elite supports server mode or client mode for the control interface.  
Selecting the right mode is required for correct interoperability with the 
connected control system. 
 
When using a control system, the Executive Elite can be configured for external 
mute  on  the  External  Control  Configuration  page  of  the  local  web  UI.    When 
external mute is On, the Executive Elite base DSP will always pass audio, even 
when  the  microphones  show  that  they  are  muted.    In  this  case  it  is  the 
responsibility  of  the  installer  to  ensure that  mute  is  performed  in  an  external 
component of the installation. 
 
NOTE: 
Both a control system and DSP cannot be connected to an 
Executive Elite Base Station at the same time. When using a 
control system and DSP at the same time, connect the Executive 
Elite Base DSP to the control system.  The external DSP must be 
controlled by the control system as well. 
 
Serial Command & Return Strings 
 
The Serial Strings of an Executive Elite Base Station begin with the Argument 
and  terminates  with  a  Carriage  Return.  The  Command  String  structure  is  as 
follows: 
 
<Argument> <Command> [ch <Channel #> <Value>] <CR> 
 
The argument is either ‘set’ or ‘get’.  A subset of the available commands is 
listed below.  For a full list of commands visit the “Executive Elite Control 
Interface” documentation. 
If specific microphone channels are affected by the command, the string ‘ch’ is 
followed by the microphone number, and then the value which is sent (‘set’ 
command).