Gorenje NRK2000P2B Manuel D’Utilisation

Page de 32
133624
28
Fault:
Cause/Remedy
The appliance does not 
operate after connection to 
the mains:
• Check if there is power in the socket and if the 
appliance is switched on.
Cooling system operates 
continuously without 
intermittent stoppages:
• Ambient temperature too high.
• Frequent opening of the door, door open too long.
• Door not closed properly (particle between door 
gasket, sagged door, check gasket sealing, etc...).
• Excessive quantity of fresh food inserted at once.
• Check air circulation for suffi cient cooling of the 
compressor, and clean the condenser.
• ‘Intensive freezing’ or ‘Intensive cooling’ option is on.
Excessive ice formation at 
the rear interior wall of the 
refrigerator:
• Frequent opening of the door, door open too long. 
• Inserting hot food in the refrigerator.
• Food or dish is touching the rear interior panel of the 
refrigerator.
• Bad door sealing; clean or replace the gasket if dirty 
or damaged.
Water dripping from the 
appliance:
• Drain outlet is clogged, drain water drips past the 
collection groove.
Alarm (refrigerator/freezer):
• Frequent opening of the door, door open too long.
• Door not closed properly (particle between door 
gasket, sagged door, damaged gasket, etc...).
• Excessively long power failure. 
• Excessive quantity of fresh food inserted at once.
• Refrigerator sensor (A) is crammed with fresh food. 
Free the sensor and allow air to circulate around it.
Troubleshooting guide