4.2 RS232 Interface 
 
User can select the desired, flow control, baud rate, parity, and data bits to be used 
in this output interface. 
4.2.1  Baud Rate / Parity / Data Bits 
The supported baud rate, parity, and data bit are listed below. 
•  Baud Rate: 115200 / 38400 / 19200 / 9600 / 4800 / 2400 / 1200 / 600 
•  Parity: None / Even / Odd 
•  Data bit: 8 / 7 
4.2.2 Flow Control 
The user can further configure the flow (handshake) control method to be used. 
The available options are listed below. 
•  No Flow Control 
•  Scanner Ready: The scanner will activate the RTS signal after power on. 
After each good read the scanner waits for an active CTS signal. The data 
will not be sent until CTS signal becomes active. 
•  Data Ready: The RTS signal will be activated after each good read. The 
scanner will then wait for the CTS signal becomes active. The data will not 
be sent until CTS signal becomes active. 
•  Inverted Data Ready: It is like the Data Ready flow control, but the RTS 
signal level is inverted. 
4.2.3 Inter-Character Delay 
An inter-character delay of 0 to 255 ms can be configured to match the computer 
response time. The delay time configured is inserted between transmitting every 
character. The longer the delay time configured, the slower the transmission speed 
will be. The inter-character delay is zero by default. 
4.3 USB Interface 
 
A USB interface is also available. For installation instructions please refer to the 
separate diskette included with your scanner. 
4.4 Memory Parameters 
 
The 1166P/1266P reserves 4 KB flash memory as transmit buffer when the scanner 
is out of service range. Data will be saved into the reserved buffer when the 
 
14
scanner is out of signal range and data will transmitted to server when the scanner 
is back to the service range. 
The 1166P/1266P can work offline and store the reading data into the internal 
Flash memory for later upload to the host. The stored data can be up to 128Kbytes.  
4.4.1  Transmit Buffer Setting 
Please enable the transmit buffer by scanning transmit buffer setting ENABLE 
label. Disable the manual memory function by scanning the DISABLE transmit 
buffer setting. 
4.4.2 Memory Mode 
Please enable the manual memory function by scanning the memory mode 
ENABLE label. Disable the manual memory function by scanning the DISABLE 
memory mode label. 
4.4.3 Clear Data 
The CLEAR label will enable the user to CLEAR or ERASE the data in the 
scanner’s memory. The user must also scan the CONFIRM label immediately after 
the CLEAR label.  
4.4.4 Send Data 
This enables the user to transmit the data in the scanner’s memory to the host. The 
interface selected by the user will be used for the transmission. During the 
transmission the red LED of 1166P/1266P will be flashing. 
4.4.5  Memory Data Delay 
This will enable the user to set a delay between each data records in memory at 