8.    Click OK button.                                                                                           
After successful connection, the Bluetooth Device Driver will report the COM 
port, which is mapped for this connection. In this case, it is COM3. You can 
also hear three serial ascending tones from the scanner indicating successful 
connection.  
After this initial connection, whenever an application program opens COM3, 
the Bluetooth driver will automatically try to connect this particular scanner. 
 
 
9.  Right click the COM1 on SW3000006 and select Disconnect to close the 
connection. There will be three serial descending tones from the scanner to indicate 
this condition. 
After the connection is closed, the 1166P/1266P and the Bluetooth driver are 
properly configured and are ready to go. User can now run their application or 
“Hyper Terminal” for testing, and make the best use of this scanner. 
 
 
24
6. Symbology Parameters 
 
This section describes user configurable parameters that are pertaining to barcode 
symbologies. 
6.1 Code39 
 
•  Standard / Full ASCII Code 39: User can choose to read either Standard 
Code 39 or Full ASCII Code 39 by configuring this parameter. 
•  Start/Stop Transmission: This parameter specifies whether the start/stop 
characters of Code 39 are included in the data being transmitted. 
•  Checksum Verification: This parameter specifies whether the scanner will 
perform checksum verification when decoding barcodes. If the checksum is 
incorrect, the barcode will not be read. 
•  Checksum Transmission: This parameter specifies whether the checksum 
character are included in the data being transmitted. 
 
6.2  Italy / French Pharmacode 
 
For Italy /French Pharmacode, there is always a checksum character included in the 
barcode. So the checksum verification is always performed when decoding these 
symbologies. User though can choose whether the checksum character is to be 
transmitted or not. The start / stop transmission of this code shares the same setting 
of Code 39. 
•  Checksum Transmission: This parameter specifies whether the checksum 
character is included in the data being transmitted. 
 
6.3  Industrial / Interleave / Matrix 25 
 
•  Start / Stop Selection: This parameter provides the readability of all 2 of 5 
symbology variants. For example, flight tickets actually use an Industrial 25 
barcode but with Interleave 25 start / stop. In order to read this barcode, the 
start / stop selection parameter of Industrial 25 should set to ‘Interleave 
25