Silex SX-550-0700 E1038 Manuel D’Utilisation

Codes de produits
E1038
Page de 122
configure the wireless security parameters.
5. Select the appropriate wireless encryption 
mode and enter the required settings (check 
with your network administrator for the proper 
settings if you do not know them). Appendix A 
lists the possible encryption settings.
Click the Submit button at the bottom of the 
window (you may need to scroll) to save your 
changes.
Now click I/O Port on the left side of the 
screen to configure the serial port.
6. Configure the serial port settings so that they 
match the settings on your device.  For 
example, if your device is set for 9600bps, 
odd parity, and XON/XOFF flow control, you 
must change the settings on the SX-550 to 
these settings.
Click the Submit button at the bottom of the 
window (you may need to scroll) to save your 
changes.
When you have finished with all your 
configuration changes, you must restart the 
SX-550 for these changes to take effect
.
You can skip the remainder of this chapter.
Using the Internal Command Console to Configure the SX-550
The Internal Command Console is a command line oriented method for configuring the SX-550.  It 
provides more comprehensive capabilities than either ExtendView or the Internal Web Pages, but is not 
as easy to use.  Advanced users may prefer to use this method because it is concise, fast, and powerful.  
To use the Internal Command Console:
1. The simplest way to access the Internal Command Console is via a terminal (for example, a 
Windows PC running the HyperTerminal Accessory program) connected to serial port 2.  If you 
are using the SX-550-6900 Evaluation Daughtercard, the included serial cable can be used for 
this purpose.  If you are not using the Evaluation Daughtercard, then you must provide the 
appropriate cable to connect pins 21, 22, and one of the ground pins on the OEM header to the 
terminal (transmit data on the SX-550 must connect to receive data on the terminal, and vice-
versa).  The terminal must be set for 115.2Kbps, 8-bit characters, no parity, and no flow control.
Part Number 40183-101
Silex SX-550 Developer's Guide
Page 29 
You may skip this section if you have completely configured the SX-550 using ExtendView or the SX-550 Internal Web 
Pages.  However, if you are using the bridge mode, you MUST use the Internal Command Console (see Chapter 4 for 
information on configuring bridge mode.