Bunn JDF-4SB Manuel D’Utilisation

Page de 57
26
SERVICE (CONT.)
Portion Control Board (JDF-2S,4S)
FIG. 25 PORTION CONTROL BOARD
P4034.25
Location:
 
The Portion Control Board is located inside the door 
cover mounted on the bracket.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  With a voltmeter, back probe check the voltage 
across pins 1 & 5 of  the J6 connector on the wir-
ing harness. Connect the dispenser to the power 
source. The indication must be 24 volts ac.
3.  Disconnect the dispenser from the power source.
If voltage is not present as described, refer to the Wiring 
Diagrams and check the dispenser wiring harness back 
to the transformer (See TRANSFORMER).
FIG. 26 CONTROL BOARD CONNECTORS
Removal and Replacement:
1.  Remove the five screws securing the door cover to 
the door frame.
2.  Carefully pull the cover forward and disconnect 
all switch harnesses from the connectors on the 
control board.
3.  Remove the four #6-20 screws securing the control 
board to the light panel.
4.  Remove the spacers from the control board and 
discard the old board.
5.  Install the spacers on to the new control board.
6.   Install new control board on the light panel using 
four #6-20 screws.
7.  Position the door cover to the door frame and 
reconnect all switch harnesses to the connectors 
on the control board.
8.  Secure the door cover to the frame with the five 
screws previously removed.
J-6
J-2
J-3
J-4
J-1
J-5
J-8
J-9
J-7
 
J-1 
Cold Water Switch
 
J-2 
Left Left Dispense Switch
 
J-3 
Left Middle Dispense Switch
 
J-4 
Right Middle Dispense Switch
 
J-5 
Right Right Dispense Switch
 
J-6 
Main Harness
 
J-7 N/A
 
J-8 N/A
 
J-9 N/A
49179  110613