SERVICE (CONT.)
Relay (all Models)
FIG. 57 RELAY
4.  Disconnect the blue/black wire and the red/black 
wires from relay terminals #4 and #6.
5.  Connect the dispenser to the power source.
6.  Turn on power and check for continuity across 
terminals on relay.
If continuity is present as described, disconnect the 
dispenser from power source and reconnect wires to 
terminals #4 and #6, the relay is working.
If continuity is not present as described, do the same 
continuity test across terminals #2 and #8. If continu-
ity is present between terminals #2 and #8, reconnect 
wires to terminals #4 and #6 instead of #2 and #8.
If continuity is not present as described, replace the 
relay.
Removal and Replacement:
1.  Disconnect the wires from the relay.
2.  Remove the two #8-32 locking screws securing the 
relay and mounting bracket to the chassis. Remove 
and discard relay.
3.  Install the new relay to the mounting bracket and 
then on the chassis using two #8-32 locking screws.
4.  Refer to Fig. 58 to reconnect the wires.
Location:
The relay (or contactor) is located inside the dis-
penser chassis on the lower outside of the component 
bracket.
Test Procedures:
1.  Disconnect the dispenser from the power source.
2.  With a voltmeter, check the voltage across the white 
wire and the white/black wire. Connect the dispenser 
to the power source. The indication must be:
 
a) 120 volts ac for 120 volt models.
 
b) 230 volts ac for 230 volt models.
3.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the Wir-
ing Diagram and check the dispenser wiring harness. 
If harness has continuity, replace Control Board.
FIG. 58 RELAY TERMINALS
Terminal #0
WHI from 
Main Harness
Terminal #6
WHI/ORN from
Main Harness
Terminal #8
BLK from
Main Harness
Terminal #1
BLK from
Main Harness
Terminal #2
Terminal #4