Eaton 5130 1250VA 2U PW5130I1250-XL2U Manuel D’Utilisation

Codes de produits
PW5130I1250-XL2U
Page de 7
3
Maximum availability for critical systems
More battery runtime for important systems. If the power
goes out, you want to reserve available battery runtime for
the most essential loads. With the 5130’s load segmentation
feature, PowerShare, you can independently control output
receptacles. You can shut down power to less essential 
loads to extend available runtime for more critical devices.
PowerShare can also be used to remotely re-boot  
locked-up network equipment or manage scheduled shutdowns and sequential startups of  
connected equipment.
Battery runtime for minutes or hours. During a power outage, internal batteries in the 5130 keep
loads running for up to 16 minutes (depending on load), long enough to gracefully shut down
systems. You can add more runtime with up to four external battery modules to run systems for
hours if necessary. Each external battery module occupies only 2U (3U for reduced depth, 3000
VA models)and provides more than an hour of runtime for a fully loaded UPS.
Service without downtime. With hot-swappable batteries, one person can replace a battery
module without disrupting data centre operations or power to protected equipment. With an
optional, multi-mount hot-swap maintenance bypass module, you can even remove and replace
the entire UPS without powering down connected loads. 
Visibility and control from anywhere
Local UPS status at a glance. LEDs on the front panel of the 5130 give you a quick read of UPS
status. Audible indicators alert you to abnormal conditions.
Are internal batteries weak or low? Is there a site wiring fault? How much load is the UPS  
supporting, relative to its capacity? Is it at risk of overload? You get up-to-the-minute answers  
to these and more critical questions.
Choice of communication options. You would expect UPSs in this class to have one slot for
a serial communications card, but the new 5130 has two built-in serial ports (one USB and
one RS-232) plus an extra slot for another communication card to support Web or SNMP.
Connectivity options are available to suit nearly any communication requirement.
Enhanced monitoring. With new card options, the UPS can communicate directly with network/
building management systems, environmental monitors, relay contact devices, multiple servers
and other UPSs—in a variety of networking environments, including the Web.
Control and visibility over 
UPS status and operation
•  LEDs and audible alarms  
 for up-to-the-minute status
•  Multiple options for  
 industry-standard  
 communications
•  LanSafe software included  
  free of charge
•  Direct monitoring via  
 existing management  
 systems and LANs
Communication cards
Front panel LEDs
load segmentation
 
        www.powerware.com.au  1300 UPS UPS 
(1300 877 877)