Pizzato Elettrica Safety button 250 Vac 6 A separate actuator momentary FK 3393-M1 IP67 1 pc(s) FK 3393-M1 Fiche De Données
Codes de produits
FK 3393-M1
Electrical data
Utilization categories
Alternate current: AC15 (50...60 Hz)
Ue (V)
Ue (V)
250
400
500
Ie (A)
6
4
1
Direct current: DC13
Ue (V)
Ue (V)
24
125
250
Ie (A)
6
1,1
0,4
Alternate current: AC15 (50...60 Hz)
Ue (V)
Ue (V)
24
120
250
Ie (A)
4
4
4
Direct current: DC13
Ue (V)
Ue (V)
24
125
250
Ie (A)
4
1,1
0,4
Thermal current (Ith):
4 A
Rated insulation voltage (Ui):
250 VAC 300 VDC
Protection against short circuits:
fuse 4 A 500 V type gG
Pollution degree:
3
with 4 poles
M12 connector
Thermal current (Ith):
2 A
Rated insulation voltage (Ui):
30 VAC 36 VDC
Protection against short circuits:
fuse 2 A 500 V type gG
Pollution degree:
3
with 8 poles
M12 connector
Alternate current: AC15 (50...60 Hz)
Ue (V)
Ue (V)
24
Ie (A)
2
Direct current: DC13
Ue (V)
Ue (V)
24
Ie (A)
2
Thermal current (Ith):
10 A
Rated insulation voltage (Ui):
500 VAC 600 VDC
400 VAC
for contact blocks 20, 21, 22, 33, 34
Protection against short circuits:
fuse 10 A 500 V type aM
Pollution degree:
3
without
connector
For the correct installation of all articles, please see “Utilization requirements” chapter, from page 6/1 to page 6/4.
Technical data
© 2005 Cop
yr
ight Pizzato Elettr
ica
General Catalog 18
page
4/11
4
General Catalog 18
page
4/12
© 2005 Cop
yr
ight Pizzato Elettr
ica
4
Markings and quality marks:
Approval IMQ:
EG610
(FR-FX-FK series)
Approval UL:
E131787
Approval EZU:
1010151
In conformity with standards:
IEC 947-5-1, IEC 337-1, EN 60947-5-1, CEI EN 60947-5-1, CEI 17-45, IEC 204-1,
EN 60204-1, CEI 44-5, EN 1088, EN ISO 12100-1, EN ISO 12100-2, IEC 529, EN
60529, CEI 70-1, NFC 63-140, VDE 0660-200, VDE 0113, CENELEC EN 50013,
BG-GS-ET-15.
IEC 947-5-1, IEC 337-1, EN 60947-5-1, CEI EN 60947-5-1, CEI 17-45, IEC 204-1,
EN 60204-1, CEI 44-5, EN 1088, EN ISO 12100-1, EN ISO 12100-2, IEC 529, EN
60529, CEI 70-1, NFC 63-140, VDE 0660-200, VDE 0113, CENELEC EN 50013,
BG-GS-ET-15.
Approvals:
IEC 947-5-1, UL 508.
IEC 947-5-1, UL 508.
General data
Ambient temperature:
Ambient temperature:
from -25°C to +80°C
Version for operation in ambient temperature from -40°C to +80° C on request
Max operating frequency:
3600 operations cycles
1
/hour
Mechanical endurance:
1 million of operations cycles
1
Max actuating speed:
0,5 m/s
Min. actuating speed:
1 mm/s
Actuator extraction force
10 N (30 N -E3 version)
(1) One operation cycle means two movements, one to close and one to open contacts, as foreseen
by IEC 947-5-1 standard.
by IEC 947-5-1 standard.
Cross section of the conductors (flexible copper wire)
Contact blocks
Contact blocks
20, 21, 22, 33, 34:
min.
1 x 0,34 mm
2
(1 x AWG 22)
max.
2 x 1,5 mm
2
(2 x AWG 16)
Contact blocks
5, 6, 7, 9:
min.
1 x 0,5 mm
2
(1 x AWG 20)
max.
2 x 2,5 mm
2
(2 x AWG 14)
Safety switches
with separate actuator
Patent pending
Housing
Made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic
resin and with double insulation
FR and FK series one conduit entry
FX series two conduit entries
FW series three knock out conduit entries
Protection degree:
Made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic
resin and with double insulation
FR and FK series one conduit entry
FX series two conduit entries
FW series three knock out conduit entries
Protection degree:
IP67 (electrical contacts)
In conformity with requirements requested by:
Low Voltage Directive 73/23/EEC and subsequent modifications and
completions. Machinery Directive 98/37/EEC.
Electromagnetic Compatibility 89/336/EEC and subsequent modifications and
completions.
Low Voltage Directive 73/23/EEC and subsequent modifications and
completions. Machinery Directive 98/37/EEC.
Electromagnetic Compatibility 89/336/EEC and subsequent modifications and
completions.
Positive contact opening in conformity with standards:
IEC 947-5-1, EN 60947-5-1, CEI EN 60947-5-1, VDE 0660-206.
IEC 947-5-1, EN 60947-5-1, CEI EN 60947-5-1, VDE 0660-206.
Main data
Housing polymer housing, from one to
three conduit entries
Protection degree IP67
9 contact blocks available
8 stainless steel actuators available
M12 assembled connector versions
Silver contacts gold plated versions
9 contact blocks available
8 stainless steel actuators available
M12 assembled connector versions
Silver contacts gold plated versions