Bunn LPGA-2E Manuel Du Propriétaire

Page de 6
4
ELECTRICAL REQUIREMENTS
 
The grinder has an attached cordset and requires 2-wire, grounded service rated 230 volts ac, 10 amp single 
phase, 50 Hz for 230V models.
OPERATING CONTROLS
Off/On/Start Switch (Models LPGA)
 
OFF - (upper position) Switching to this position stops all operation of the grinder.
 
ON - (middle position) The switch will return to this position after a grind cycle has begun and will remain 
in this position after grinding has ceased.
 
START - (lower, momentary position) Pressing the switch to this position and releasing initiates a grind cycle.
27091.1 061112
CE REQUIREMENTS
• This appliance must be installed in locations where it can be overseen by trained personnel.
• For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C.
• Appliance shall not be tilted more than 10° for safe operation.
• An electrician must provide electrical service as specified in conformance with all local and national codes.
• This appliance must not be cleaned by water jet.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental 
capabilities, or lack of experience and knowledge, unless they have been given instructions concerning use of 
this appliance by a person responsible for its safety.
• Children should be supervised to ensure they do not play with the appliance.
• If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel with 
a special cord available from the manufacturer or its authorized service personnel in order to avoid a hazard.
• Machine must not be immersed for cleaning.
• Machine rated IPX1.
PREVENTIVE MAINTENANCE
Bunn-O-Matic
®
 Corporation recommends that preventive maintenance be performed at regular intervals. Maintenance 
should be performed by a qualified service technician. For Technical Service, contact Bunn-O-Matic
®
 Corporation at 
1-800-286-6070.
NOTE: Replacement parts or service caused by failure to perform required maintenance is not covered by warranty.
6-Month 
Weekly Cleaning plus replace the dechaffer assembly.
1-Year
1.  On grinders with slide plates check the slide plates and clean. 
2.  Inspect and clean/replace burrs and grind chamber if necessary.
3.  Adjust the burrs and grind time to your specifications for particulate size and throw weight.