Bunn RT Manuel Du Propriétaire

Page de 35
Page 21
FIG. 18 INDICATOR LAMP WIRING
FIG. 16 INDICATOR LAMP - MODEL OT
FIG. 17 INDICATOR LAMP - MODEL RT
SERVICE (cont.)
Indicator Lamp(s)
4.  Disconnect the brewer from the power source.
If voltage is present, the indicator lamp is operating 
properly.
If voltage is not present, replace the indicator lamp.
Removal and Replacement:
1.  Compress the clips inside the housing and gently 
push the indicator lamp through the opening.
2.  Remove the wires from the indicator lamp termi-
nals.
3.  Refer to FIG. 18 when reconnecting the wires.
4.  Push the new indicator lamp firmly into the 
opening.
Location:
The indicator lamps are located beneath their associ-
ated warmers, FIG.s 16 and 17.
Test Procedure:
1.  Check continuity of the black wire from the switch 
to the indicator lamp.
2.  Check continuity of the white or red wire from 
the indicator lamp to the terminal block.
If continuity is present, proceed to #3.
If continuity is not present, refer to Wiring Diagrams 
and check brewer wiring harness.
3.  Check for voltage across the indicator lamp ter-
minals. Connect the brewer to the power source. 
The indication must be:
 
a) 120 volts ac for two wire 120 volt models.
 
b) 200 or 240 volts ac for two wire 200 volt or 
240 volt models and three wire 120/240 volt 
models.
 
c) 100 volts ac for two wire 100 volt models.
MODEL
OT Upper 
BLK 
to Warmer Switch
 
WHI or RED 
to Warmer
 
 
to Harness P2
OT Lower 
BLK 
to Start Switch
 
 
to On/Off Brew Station Warmer  
 
 
 Switch
 
WHI or RED 
to Timer P2
 
 
to Brew Station Warmer
  
RT 
BLK 
to Start Switch
 
 
to On/Off Brew Station Warmer  
 
 
 Switch
 
WHI or RED 
to Right Front Warmer
 
 
to Left Front Warmer
WHI or RED
 (see below)
BLK (see below)
P1687
P1688
P1694
32440 070700