Bunn LCR-2 Manuel Du Propriétaire

Page de 38
6
L1
L2
L3
N
L1
FOR 3-PHASE OPERATION
CONNECT INPUT WIRING TO
L1,L2,L3 & N AS SHOWN.
FOR 1-PHASE/15 AMP. OPERATION
CONNECT INPUT WIRING TO
L1 & N AS SHOWN.
N
RED
BRN
BLU
TERMINAL
BLOCK
TO MACHINE
FROM POWER SOURCE
TO MACHINE
FROM POWER SOURCE
L1
L2
L3
N
BLK
RED
BRN
BLK
BRN
BLU
L2
L3
BLK
L1
L2
L3
N
L1
N
RED
BLU
TO MACHINE
FROM POWER SOURCE
L1
N
FOR 1-PHASE/30 AMP. OPERATION
MOVE BLACK WIRE INTO
TERMINAL BLOCK WITH BROWN
WIRE, CONNECT INPUT WIRING
TO L1 & N AS SHOWN.
PLUMBING REQUIREMENTS
The dispenser may be connected to a cold or hot water system (140°F Max.) with operating pressure between 20 and 90 
psi (138 and 620 kPa) from a 1/2” or larger supply line.  A shut-off valve should be installed in the line before the dispenser.  
Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa).  The water 
inlet fitting is 3/8” flare. Dispensers set up to deliver to 1.8 Oz./sec. (53.2 ml/sec) per dispense tip, require a water supply 
source that can deliver a minimum of 1.7 gpm (6.4 lpm) at the inlet fitting. Dispensers set up to deliver 2.6 Oz./sec. (76.9 
lpm) per dispense tip, require a water supply source that can deliver a minimum of 2.4 gpm (9.2 lpm) at the inlet fitting. 
NOTE:  Bunn-O-Matic recommends 3/8” tubing from the 1/2” water supply line.  At least 18 inches of FDA approved flexible 
beverage tubing, such as reinforced braided polyethylene or silicone, before the dispenser will facilitate movement to clean 
the counter top. Bunn-O-Matic does not recommend the use of a saddle valve to install the dispenser.  The size and shape 
of the hole made in the supply line by this type of device may restrict water flow.
NOTE: Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed, and 
maintained in accordance with federal, state, and local codes.
36026.1 010313
As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the 
Food and Drug Administration (FDA), this equipment must be installed with adequate backflow prevention to comply 
with federal, state and local codes. For models installed outside the U.S.A., you must comply with the applicable 
Plumbing /Sanitation Code for your area.
ELECTRICAL REQUIREMENTS (Cont.)
CAUTION:  The dispenser must remain disconnected from power source until specified in Electrical Hook-Up.
 
The LCR-2A 3 Phase dispenser is internally wired from the factory for 400 Volts AC Phase to Phase, 230 Volts AC 
Phase to Neutral, 3 Phase 50/60 Hz. It requires a 4-wire, grounded, individual branch circuit rated for 400 Volts AC, 
Three Phase, 50/60 Hz. At Three Phase operation, each Phase will have approximately 13.5-14.0 Amps flow through 
it.
 
The LCR-2A 3 Phase dispenser can be Field Wired for 230 Volts AC, Single Phase applications. This requires a 2-wire, 
grounded, individual branch circuit rated for 230 volts AC, Single Phase, 50/60 Hz. At Single Phase operation, the 
machine will have approximately 27.5 Amps flow through it.
NOTE:   The internal terminal block must be rewired for 230 Volts AC, Single Phase applications, (see Optional Field Wiring 
Diagram).
CE REQUIREMENTS
• This appliance must be installed in locations where it can be overseen by trained personnel.
• For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C.
• Appliance shall not be tilted more than 10° for safe operation.
• An electrician must provide electrical service as specified in conformance with all local and national codes.
• This appliance must not be cleaned by water jet.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabili-
ties, or lack of experience and knowledge, unless they have been given instructions concerning use of this appliance by 
a person responsible for its safety.
• Children should be supervised to ensure they do not play with the appliance.
• If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel with a special 
cord available from the manufacturer or its authorized service personnel in order to avoid a hazard.
• Machine must not be immersed for cleaning.
The LCR-2A dispenser is internally wired from the 
factory for 230 Volts AC Single Phase 50/60 Hz. 
It requires a 2-wire, grounded, individual branch 
circuit rated for 230 Volts AC.
L2 RED
L1 BLACK
200, 230 or
240V A.C.
230V A.C.